The purpose of this study was to conduct a literature review of ANSI/ASHE/ASHRAE Standard 170 Ventilation of Health Care Facilities to determine whether the 886 requirements defined in the Standard (Part 4 of the FGI Guidelines) are supported by engineering and/or scientific evidence. The authors and the Project Monitoring Subcommittee (PMS) assigned the requirements to one of three categories: rational inclusion, clinical inclusion and evidence-based inclusion.

Those requirements categorized for evidence-based inclusion were aligned with related citations. The authors provided opinions on whether the available evidence suggests that the requirement is a basic necessity or an enhanced requirement, requires a change to the Standard, is procedural or requires further investigation.

Overall, 209 requirements (23.6%) were determined to be a basic necessity as supported by rational inclusion, clinical requirements or evidence and six requirements (0.7%) were considered to be enhanced practices. Twelve requirements (1.4%) were determined to be procedural and not subject to evidence. Evidence was found to support a change to the standard for eight requirements (0.9%). The remaining 651 requirements (73.5%) are recommended for further study.

 

 Access PDF Members can download a PDF of the entire monograph
Order print version Catalog number: 055399
Member: $25.00, Nonmember: $35.00

 

 

Related Resources

Book
Introduction to Health Care Facilities Management: This award-winning, in-depth 130+ page introductory book provides an orientation to the dynamic…
Lunch and Learn
Walk through the electrical safety roadmap from pre-design through installation and post-installation.
Lunch and Learn
This course will walk participants through site acceptance and in-service testing and will review best practices that will empower facility owners…
On-Demand Educational Webinars
in this session we will explore the unintended consequences of having so many sinks. We will explore the dynamics of transmission from patient to…
Lunch and Learn
In this webinar, the presenters will review current and proposed CMS/TJC requirements in the context of ASHRAE 188 and will discuss practical…
Lunch and Learn
This presentation will provide an overview of annual fire door inspection requirements, strategies for remediation of non-compliant issues and on-…